740 Power Rd Mesa, AZ 85206 / 5220

(UPDATED: 07/25/2024)
Property Report

Information about property on 740 Power Rd, Mesa AZ, 85206-5220. Find out owner contacts, building history, price, neighborhood at Homemetry Address Directory.

Property Details

Householders and Tenants for 740 Power Rd, Mesa AZ

Businesses

Organization Phone Number Additional Info
eikonJRHi
Categories:
Other
Jeff Peterson
480-985-****
480-854-****
Organization:
Red Mountain Christian Ctr
Title:
Religious Leader
Industry:
Religious Organization
Site:
rmcconline.org
Red Mountain Christian Center Inc
480-985-****
480-854-****
Categories:
Churches
Industry:
Religious Organization
SIC:
8661 - Religious Organizations
SIC6:
866107 - Churches
Site:
rmcconline.org
VIA CHURCH, INC

Where is 740 Power Rd, Mesa AZ located on map?

Building Permits

To date, we have no information about building permits in 2024
Jul 27, 2015
Description: Removal of 553 sf of existing sidewalk on poer road and installation of 1,319 sf of new sidewalk on power rd.
  • Fee: $780.00 paid to City of Mesa, Arizona
  • Client: Via Church Inc
  • Parcel #: 14162013M
  • Permit #: BLD2015-04362
Oct 9, 2012
Description: Pbi - adding 1- 200 amp panel
  • Fee: $449.28 paid to City of Mesa, Arizona
  • Client: Red Mtn Christain Cntr Assem Of God
  • Parcel #: 14162013M
  • Permit #: BLD2012-05038
Jan 4, 2008
Description: Install a new approx. 1764 sq ft fabric shade canopy/sails attached to buildings over existing courtyard. special inspections required for pier foundation/caisson and epoxy adhesive anchors which are mounted on the surrounding buildings. structural eng apprvoed by eng #43545 ken-an lou. canopy is not to be considered one building or part of the surrounding buildings. see case notes for approval per steve hether. occupancy identified for canopy as an (a-3/type iib) construction - meets fire sprinklers exception 903.2. per interpretation by zoning administrator this structure is considered a church spire and is allowed to exceed the height limits specified in the zoning ordinance 11-13-2 (g).
  • Fee: $580.00 paid to City of Mesa, Arizona
  • Client: Red Mtn Christain Cntr Assem Of God
  • Parcel #: 14162013M
  • Permit #: BLD2007-11664
Aug 28, 2006
Description: Fee collection for second temp. c of o extension for 10 days. temp. c of o will expire 10 days from 8/28/06.
  • Fee: $200.00 paid to City of Mesa, Arizona
  • Client: Red Mtn Christain Cntr Assem Of God
  • Parcel #: 14162013M
  • Permit #: BLD2006-08539
Apr 5, 2005
Description: New 31,775 sq ft two story masonry building w/basement and pre-manufactured wood trusses with concrete tile and foam roofing system (class 'a' roof covering) & remodel of 2,500 sf (enclosing 266 sf of the cover entry) of existing worship center. building and site ada compliant. basement contains 5680 sf of classrooms and the rest is storage. occupant load = 292. (2) exits required; (2) exits provided with panic hardware (one is rated stair enclosure). 1 hour fire barrier with rated ceilings around elevator room and mechanical room. fire rated elevator shaft. first floor contains the 3840 sf kids church with 963 sf mezzanine (2 exit from mezzanine) and 630 sfplatform (no curtian), 476 sf cafe and 1,119 sf kitchen, and 1,342 sf lobby. occupant load 896. (3) exits required; (3) exits provided. 1 hour shaft around restroom exhaust duct and grease duct. 2nd floor contains 3485 sf of office. occupant load = 119. (2) exits required; (3) exits provided (one is fire rated stair enclosure). fire rated ceilings in some parts of the basement , 1st floor, and the second floor - see reflective ceiling plan. special inspections required - see conditions. smoke detectors in supply for automatic shutdown of air handlers. fire dampers at rated assemblies. 1250 gallon grease interceptor and oil interceptor for the elevator sump discharge. duplex sewage ejector pumps for basement plumbing fixtures. water pfus = 356. cross connection control devices. gas appliances include (2) 80k water heaters, 400k makeup air unit, 54k steamer, 310k range, 80k griddle, and 55k oven. total btus = 1,059,000. total developed length = 125'. exterior emergency lighting. gfci receptacles in kitchen. 1200 amp 277/480v 22k/14k two-tier series rated ses and equipment. impact fees assessed. applicant has elected to defer the following fire protection systems: kitchen fire suppression system. installation of deferred submittal systems is not permitted until plans have been approved and issued. no certificate of occupancy, certificate of compliance, or building final will be granted until such systems are approved and pass final inspection. applicant is solely responsible for securing such permits in a timely fashion in accord with their construction schedule.
  • Fee: $56,863.49 paid to City of Mesa, Arizona
  • Client: Red Mtn Christain Cntr Assem Of God
  • Parcel #: 14162013M
  • Permit #: BLD2004-09139
Description: Fire damage-supt. explained how fire was started. no damage except for spalding of concrete which was removed. supt has eng. report regarding steel trusses. received eng report. no plans required.
  • Client: Red Mtn Christain Cntr Assem Of God
  • Parcel #: 14162013M
  • Permit #: BLD2005-09868

740 Power Rd Fire Incident History

To date, we have no information about fire incidents in 2024
08 Sep 2005 Outside gas or vapor combustion explosion
Property Use —
Church, mosque, synagogue, temple, chapel
Area of Origin —
Assembly area - less than 100 persons
First Ignition —
Pipe, duct, conduit, hose covering
Heat Source —
Spark, ember or flame from operating equipment

Power Rd Fire Incident History

To date, we have no information about fire incidents in 2024
12 Aug 2019 Passenger vehicle fire
Property Use —
Vehicle parking area
04 Jun 2019 Road freight or transport vehicle fire
Property Use —
Street, other
Area of Origin —
Cargo/trunk area - all vehicles
20 Nov 2018 Passenger vehicle fire
Property Use —
Vehicle parking area
Area of Origin —
Engine area, running gear, wheel area
02 Oct 2018 Passenger vehicle fire
Property Use —
Vacant lot
Area of Origin —
Engine area, running gear, wheel area
First Ignition —
Electrical wire, cable insulation
Heat Source —
Hot or smoldering object, other

View more

Power Rd Incidents registered in FEMA
(Federal Emergency Management Agency)

To date, we have no information about incidents registered in FEMA in 2024
24 Nov 2015 Passenger vehicle fire
24 Oct 2015 Gasoline or other flammable liquid spill
Property Use —
Service station, gas station
01 Oct 2015 Trash or rubbish fire, contained
Property Use —
Property Use, other
04 Sep 2015 Chemical spill or leak
Property Use —
Vehicle parking area

View more

Properties Nearby

 

FAQ about the house at 740 Power Rd, Mesa, AZ


NOTICE: You may not use HudwayGlass or the information it provides to make decisions about employment, credit, housing or any other purpose that would require Fair Credit Reporting Act (FCRA) compliance. HudwayGlass is not a Consumer Reporting Agency (CRA) as defined by the FCRA and does not provide consumer reports.